الصفحة الرئيسية / الادویة و المستلزمات الطبیة / الادوية والمستلزمات الطبية ليوم 3-12-2018

الادوية والمستلزمات الطبية ليوم 3-12-2018

print

مستشفى الحويجة العام

3-12-2018

ت اسم المادة العدد
Urin strip 1000علبة
انتي بايتك دسك 100
برنر 1
لوب للزرع 500
HBS STRIP 1500
HCV STRIP 1500
HIV STRIP 1500
HBS  KIT 2
HCV  KIT 2
HIV  KIT 2
Cel pake 20
Stromatolyzer 14
Cel clean 2
 

Gel tube

15000
Fast ESR tube 2000
cuvate 5000

 


 

 

 

 

مشتريات مستشفى أزادي التعليمي 3-12-2018     

جهاز dry biochemistry fuji film NX 500 I  العدد أثنان يتوفر فيه شهادة

 FDAأو  CE

سنتان ضمان

ثلاثة سنوات صيانة

 

حسب المواصفات ادناه  ..

Semi automated Clinical analyzer specifications

 

 

 

 

SAMPLE Type: Whole blood, plasma, serum

 

SAMPLE Size/range, mL : to be stated as minimum

 

INCUBATOR: yes

 

Capacity,(No. of tubes or strip) : to be stated

 

CALIBRATION: Chemical standards, control serums

 

DATA OUTPUT: LCD, printer

 

LINE POWER, VAC:  220V,50Hz

 

Other consideration:

 

-Ease of use

-Error message alert

-Guide on routine use of control materials

-Generated waste should be handled or packed in a safe way.

-Ease of routine maintenance

-High accuracy and stability

-Large linearity

-Built in data management with high memory

1)Compact microprocessor – controlled, general purpose bi-chromatic photometer or spectrophotometer ranging from 340 nm to 700 nm, to read & calculate results of both end

point & Kinetic colorimetric assays.

2)Temperature control: 37°C, 30°C, 25°C ± 0.1°C.

3)Light source – tungsten Halogen lamp with a standby mode and lamp life measurement.

4)Measurement modes – Absorbance, Concentration turbidometry.

5)Calculation modes – single standard, multistandard – linear & nonlinear, factor, kinetic

6)Output – LCD display and built in printer & facility to attach external printer.

7)Measurement range 0.00 to 2.50 absorbance units (A)

8)Measuring device: Facility to use both cuvettes and flow cells

9)Ability to generate patient work list, reports and quality control data for not less than two levels for 50 parameters or more.

10) Facility to transfer data via LIS

11)Store reagent performance data (blank absorbance),calibration curves, Levy-Jenning plots and not less than 1000 patient results

12)Compatible online UPS with battery backup of at least 30min.


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

أضف تعليقاً

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *